Instruments > All Round Potentiostats for all Applications
IviumStat2X

The complete high-end potentiostat

The IviumStat2X is a dual-compliance instrument switchable between ±5A/±10V and ±2A/±50V. It has super high resolution, ultra low current sensitivity and 8MHz EIS capability.

±5A/±10V or ±2A/±50V
Integrated EIS 8MHz
Zepto-Ampere resolution
Request Info
User-selectable compliance, allowing you to adapt to ever changing demands in your research.
High frequency EIS to unlock non-destructive insights into complex reaction kinetics and surface properties.
Super-high 24-bit resolution and an ultra-low 1pA range gives a current resolution down to prefixes you need to google.

Specifications

Key Specs

Maximum current
±5A
Compliance voltage
±50V
Maximum applied potential
±10V
EIS frequency range
10μHz to 8MHz
Electrode Connections
4: WE, CE, RE, S (+GND)
Maximum sampling rate
2,000,000 samples/s
IR compensation
Yes

Potentiostat

Maximum applied potential
±10V
Applied potential accuracy
0.2% or 2mV
Current ranges
±1pA to ±10A
Measured current resolution
0.00005% of current range, minimum 0.5zA
Measured current accuracy
20pA + 0.025% FSR

Galvanostat

Applied current ranges
±10pA to ±10A
Applied current accuracy
0.2% of value or 0.1% of current range
Applied current resolution
0.002% of applied current range
Potential ranges
±1mV, ±4mV,±10mV,±40mV, ±100mV,±400mV, ±1V,±4V, ±10V
Measured potential accuracy
0.2% or 1mV
Measured potential resolution
0.00001% of potential range, minimum 0.15nV

Impedance Analyser

EIS Frequency range
10μHz to 8MHz
EIS Amplitude
0.02mV to 2.0V or 0.03% to 100% of current range

IviumSoft

Free and included powerful electrochemical software

IviumStat2X

Size
26 x 33 x 12cm
Weight
4.2kg

Requirements

Power requirements
100-240V, 47-63Hz, 150VA
Interfacing
USB
PC requirements
Windows 8 or higher

Includes

Cell cable standard USB connection cable Power adapter Electrode clips Test cell Full IviumSoft electrochemical software

Get in touch

We're here to help with:

  • Instrument pricing and quotations
  • Selecting the right instrument
  • Technical questions
  • Hardware and software support